| Http Server Functions/ Web Pages | FP | |
|
|
|
|
|
|
|
|
| Http Address | Function |
|
| http://199.199.26.52/plc?yyy | Downloads HTML page yyy.MTM including PLC data. The |
|
|
| file format .MTM is equivalent to the .HTM format plus PLC |
|
|
| data. The .MTM file is generated by the Configurator. |
|
| http://199.199.26.52/plc?yyy&U=xx | With automatic reload/ update after xx seconds. The |
|
|
| maximum refresh rate is reached with the input &U=0. |
|
|
| For rapidly changing PLC data, we recommend using Java |
|
|
| Applets (see page 158), which can handle a much higher |
|
|
| data update/display rate. |
|
| http://199.199.26.52/plc?yyy&A=xx | All following PLC data displayed (including yyy.MTM) are |
|
|
| addressed to the PLC with the |
|
|
| Address xx (0..32). 0 is equivalent to the universal address |
|
|
| EE. The default address (if no &A parameter is used) can |
|
|
| be determined in the base configuration setting PLC |
|
|
| MEWTOCOL Address. The &A operator does not affect |
|
|
| the default addressing for input fields. |
|
| http://199.199.26.52/plc?yyy&Rxxy=w | Before downloading the page yyy, the internal relay with |
|
|
| the address Rxxy is set (w=1) or reset (w=0). (xx=0...999 |
|
|
| y=0...F w=0/1) |
|
| http://199.199.26.52/plc?yyy&Yxxy=w | Before downloading the page yyy, the output with the |
|
|
| address Yxxy is set/ reset. (xx=0...999 y=0...F w=0/1) |
|
| http://199.199.26.52/plc?yyy&Y0=1&A=5&Y | Composed types of commands are also possible! |
|
| 0=1 |
|
|
Comments:
•http://199.199.26.52/' can be omitted for relative hyperlinks in an .HTM (or .MTM).
•Only when the http server is turned on can the modification of PLC data (via &Y and &R commands) be temporarily turned off. If an error occurs, writing to the PLC may be prevented. Therefore the functioning of the Ys and Rs is also affected.
•The functions &Y and &R can be limited with [Add. Range].
•The name of the CGI function must be in small letters, i.e. "http://199.199.26.52/PLC?yyy" will not work.
•The PLC address of the &R and &Y commands cannot be replaced by a variable name, i.e. "http://199.199.26.52/plc?yyyeR'name'=1" will not work. For further information, refer to Using Variable Names Instead of Absolute PLC Addresses (see page 82).
•If spaces or Japanese characters are used, an error message pops up before transmission to the FP
•All file names have to correspond to the DOS 8.3 format, i.e. the name may only have up to 8 characters and the extension (type) only up to 3 characters after the period.
For programming examples in C++ and Java to control PLC relays via the http function, please refer to the online help under the keyword "Appendix K) Programming Samples: Access to the FP