Technical Information

PJLinkTMprotocol

The network function of the projector supports PJLink™ class 1, and the PJLink™ protocol can be used to perform projector setting and projector status query operations from a computer.

Control commands

Command

Control details

 

 

Parameters/Notes

 

POWR

Power supply control

0

=

Standby

1

=

Power ON

POWR ?

Power supply status query

0

=

Standby

1

=

Power ON

2

=

Cool-down in progress

2

=

Warm-up in progress

 

 

INPT

Input selection

11

=

RGB1

12

=

RGB2

 

 

21

=

VIDEO

22

=

S-VIDEO

INPT ?

Input selection query

31

=

DVI-D

32

=

SDI (PT-DZ6710 only)

AVMT

Shutter control

30

=

Shutter mode off (picture mute cancelled)

AVMT ?

Shutter mode query

31

=

Shutter mode on (picture mute)

 

 

 

 

1st byte: Indicates fan errors, range 0 - 2.

 

 

 

 

2nd byte: Indicates lamp errors, range 0 - 2.

 

 

 

 

3rd byte: Indicates temperature errors, range 0 - 2.

 

 

4th byte: Indicates cover open errors, range 0 - 2.

 

ERST ?

Error status query

5th byte: Indicates filter errors, range 0 - 2.

 

 

 

 

6th byte: Indicates other errors, range 0 - 2.

 

 

 

 

Definitions for each value from 0 - 2 are as follows.

 

 

0

=

No error known

 

 

 

 

 

1

=

Warning

2

=

Error

 

 

1st digits (1 - 5 digits):

Lamp 1 cumulative operating time

LAMP ?

Lamp status query

2nd digit:

 

0 = Lamp 1 off, 1 = Lamp 1 on

3rd digits (1 - 5 digits):

Lamp 2 cumulative operating time

 

 

 

 

4th digit:

 

0 = Lamp 2 off, 1 = Lamp 2 on

 

 

The following are returned as parameters.

 

 

INST ?

Input selection list query

“11 12 21 22 31” for PT-DZ6700,PT-DW6300,PT-D6000 and PT-D5000

 

 

“11 12 21 22 31 32” for PT-DZ6710

 

 

 

NAME ?

Projector name query

The name set for PROJECTOR NAME in NETWORK menu.

INF1 ?

Manufacturer name query

“Panasonic” is returned.

 

 

 

INF2 ?

Model name query

“DZ6710, DZ6700, DW6300, D6000 or D5000 is returned.

INF0 ?

Other information query

Information such as version number is returned.

 

CLSS ?

Class information.

“1” is returned

 

 

 

 

 

 

 

 

 

 

 

PJLink™ security authorization

When using PJLink™ with security authorization, either of the password set for administrator privileges and the password set for user privileges with web browser control can be used as the password for PJLink™. When using PJLink™ without security authorization, set use without the password for administrator privileges and the password for user privileges of web browser control.

PJLink™ is a pending trademark in Japan, the United States, and other countries and regions. For specifications regarding PJLink™, refer to the Japan Business Machine and Information System Industries Association website.

URL: http://pjlink.jbmia.or.jp/

Appendix

ENGLISH - 44

Page 44
Image 44