Technical Information

Basic format

STX

Start

(1 byte)

A

D

 

 

I 1

I 2

 

;

 

 

C1

C2

C3

 

:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2 bytes)

 

 

 

 

 

Semicolon

 

 

 

 

 

 

Colon

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1byte)

 

 

 

 

 

(1byte)

 

 

 

2 ID characters

 

 

 

 

 

 

 

 

 

 

 

 

(2 bytes)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZZ, 01 to 64 and 0A to 0Z

 

3 command

 

characters

 

 

 

 

 

 

ID designate

 

 

 

 

 

(3 bytes)

 

 

 

P1

P2

-

Pn

 

ETX

 

 

 

 

 

 

Parameter

(undefined length)

End

(1 byte)

NOTE:

No command can be sent or received for 10 to 60 seconds after the lamp starts lighting. Try sending any command after that period has elapsed.

When transmitting multiple commands, be sure to wait until 0.5 seconds has elapsed after receiving the response from the projector before sending the next command. When sending commands without parameters, a colon (:) is not necessary.

When the wrong command is sent, the “ER401” or “ER402” status is sent from the projector to the personal computer.

Projector ID supported on the RS-232C interface is ZZ (ALL) and a group of 01 to 64 and 0A to 0Z.

The “STX” character code is 02 and the “ETX” character code is 03.

If a command is sent with a projector ID specified, the projector will return answer back only in the following cases: If it coincides with the projector ID

If the ID specification is ALL and responding (ID ALL) is on

If the ID specification is Group and responding (ID Group) is on

Cable specifications

(When connected to a computer)

Projector

NC

NC

NC

NC

NC

NC

Computer (DTE)

Appendix

 

 

NC

 

NC

 

Control commands

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command

Control contents

 

 

 

 

 

Parameter/Remarks

PON

Power ON

In standby mode, all commands other than the PON command are ignored.

POF

Power OFF

 

 

The PON command is ignored during lamp ON control.

 

 

 

 

 

 

 

QPW

Power query

000 = Standby

 

001 = Power ON

 

 

 

 

 

 

 

 

Switch input modes

VID = VIDEO

 

SVD = S-VIDEO

IIS

RG1 = RGB1

 

RG2 = RGB2

 

 

DVI = DVI

 

SDI = SDI (PT-DZ6710 only)

 

Query for active lamp

0

= DUAL

1

= SINGLE

QSL

2

= Only LAMP 1 is on

3

= Only LAMP 2 is on

mode

 

 

 

SINGLE will use the lamp (LAMP 1 or LAMP 2) with shorter operating hours.

 

 

 

 

LPM

Active lamp mode

0

= DUAL

1

= SINGLE

2

= Only LAMP 1 is on

3

= Only LAMP 2 is on

 

 

OLP *

Lamp power setting

0

= HIGH

1

= LOW

 

 

 

 

 

 

 

 

 

* Not available for PT-D5000.

ENGLISH - 46

Page 46
Image 46
Panasonic PT-D6000, PT-D5000, PT-DW6300, PT-DZ6700 manual Technical Information Basic format, Cable specifications