On-screen displayLAMP indicator

 

 

 

 

 

 

 

Displayed for 30

 

More than 1 350 hoursseconds. Pressing any

 

button will clear the

Illuminates red during

 

 

display.

image projection and

 

 

standby mode.

More than 1 500 hoursRemains displayed until

 

any button is pressed.

 

 

 

 

 

 

Lamp unit replacement procedure

NOTE:

BIf the lamp usage time has passed 1 500 hours (when “LAMP POWER” has been set to “HIGH”), the projector will switch to standby mode after

approximately 10 minutes of operation. The steps

) to . on the next

page should thus be completed within 10 minutes.

 

#Turn off the MAIN POWER switch according to the procedure given in “Turning off the power” on page 26, and then disconnect the power

cord plug from the wall outlet and check that the area around the lamp unit has cooled down.

$Use a Phillips screwdriver to turn the air outlet port fixing screws at the back of the projector, and then open the air outlet port.

Air outlet port

Air outlet port fixing screws

%Use a Phillips screwdriver to loosen the two lamp unit fixing screws until the screws turn freely. Then hold the handle of the lamp unit and gently pull it out from the projector.

Lamp unit fixing screwsHandle

&Insert the new lamp unit while making sure that the direction of insertion is correct, and then use a Phillips screwdriver to securely tighten the lamp unit fixing screws.

58-ENGLISH