When the TEMP indicator and the
LAMP indicator are illuminated
There are two indicators on the control panel of the projector which give information about the operating condition of the projector. These indicators illuminate or flash to warn you about problems that have occurred inside the projector, so if you notice that one of the indicators is on, turn off the power and check the table below for the cause of the problem.
|
| LAMP indicator |
|
| TEMP indicator |
RGB INPUT | LAMP | TEMP |
|
| INPUT |
AUTO SETUP | VIDEO | RGB SHUTTER |
Indicator | Illuminated (red) | Flashing (red) | |
display | (Lamp unit on) | (Lamp unit off) | |
|
|
| |
| The surrounding temperature or | The surrounding temperature or | |
| the temperature inside the | the temperature inside the | |
Problem | projector has become unusually | projector has become | |
high. | dangerously high, causing the | ||
| |||
|
| lamp unit to automatically shut | |
|
| off. | |
|
|
| |
Possible | BThe ventilation holes may be covered. |
| |
BThe ambient temperature in the place of use may be too high. | |||
cause | |||
BThe air filter may be blocked. |
| ||
|
| ||
|
|
| |
| BUncover the ventilation holes. |
| |
| BSet up the projector in a place where the temperature is | ||
| between 0 °C (32 °F) and 40 °C (104 °F) and the humidity is | ||
| between 20% and 80% (with no condensation). [If you set the | ||
Remedy | “FAN CONTROL” to “HIGH” (page 48), set up the projector in a | ||
place where the temperature is between 0 °C (32 °F) and 35 °C | |||
| |||
| (95 °F) and the humidity is between 20% and 80% (with no | ||
| condensation).] |
| |
| BTurn off the MAIN POWER switch by following the procedure | ||
| on page 26, and then clean the air filter (refer to page 56). | ||
|
|
|