Panasonic WV-CL920, WV-CL924 White Balance Setting White BAL, Auto-Tracing White Balance Mode ATW

Models: WV-CL920 WV-CL924

1 43
Download 43 pages 54.21 Kb
Page 32
Image 32

To reset COARSE and FINE to the values pre-

set at the factory, press and simulta- neously. COARSE and FINE adjustments are preset at the factory to zero-crossing of the AC line phase.

If the AC line contains noise (spike noise, etc.), the stability of the vertical phase of the camera video output signal may be disturbed.

7.White Balance Setting (WHITE BAL)

7-1. Auto-Tracing White Balance Mode (ATW)

You can select one of four modes for white balance adjustment as follows:

ATW1 (Auto Tracing White Balance 1)

In this mode, the color temperature is monitored continuously and thereby white balance is set auto- matically. The color temperature range for the prop- er white balance is approximately 2 600 - 6 000K. Proper white balance may not be obtained under the following conditions:

1.The color temperature is out of the 2 600 - 6 000K range.

2.When the scene contains mostly high color temperature objects, such as a blue sky or sunset.

3.When the scene is dim.

In these cases, select the AWC mode.

Move the cursor to the WHITE BAL parameter and select ATW1. The white balance of the camera is automatically set.

 

** CAM SET UP **

CAMERA ID

OFF

ALC/ELC

ALC

SHUTTER

OFF

 

 

AGC

 

ON (DNR-H)

SENS

UP

OFF

 

 

SYNC

 

INT

 

 

WHITE BAL

ATW1

MOTION DET

OFF

 

 

LENS

DRIVE

DC

 

 

END

SET UP ENABLE

ATW2 (Auto Tracing White Balance 2) Auto-tracing white balance of the sodium light mode (ATW2)

In case that you select ATW2 for sodium light, white balance is set automatically (Operation is not needed).

Note: ATW1 and ATW2 do not appear for the WHITE BAL parameter on the system con- troller setup menu.