6.The VS gen-lock mode has a submenu for horizon- tal phase adjustments. When the cable length of the video output or the gen-lock input is changed, the horizontal phase must be re-adjusted.

7.The line-lock mode has a submenu for line-lock vertical phase adjustment. If the camera installation is relocated, check the vertical phase adjustment again since the AC line phase may be different.

6-1. VBS Gen-lock Mode (EXT(VBS))

 

** CAM SET UP **

** CAM SET UP **

CAMERA ID

OFF

CAMERA ID

OFF

ALC/ELC

ALC

ALC/ELC

 

ALC

SHUTTER

OFF

 

SHUTTER

 

OFF

 

 

AGC

 

ON (DNR-H)

AGC

 

ON (DNR-H)

SENS

UP

OFF

 

SENS UP

 

OFF

 

 

SYNC

 

INT

 

SYNC

 

EXT(VBS)

 

WHITE BAL

ATW1

WHITE BAL

ATW1

 

MOTION DET

OFF

 

MOTION DET

OFF

 

 

LENS

DRIVE

DC

 

LENS DRIVE

DC

 

 

END

SET UP ENABLE

END

SET UP ENABLE

1.Move the cursor to the SYNC parameter and select INT.

2.Connect the coaxial cable for the blackburst or composite color video signal to the gen-lock input connector.

3.Confirm that the INT parameter changed to EXT (VBS) on the menu.

Caution: The gen-lock input signal should meet the EIA RS-170A specifications and should not contain jitter, such as a VCR playback signal, as it could disturb synchronization.

4.After confirming that the cursor is on EXT (VBS),

press . The phase adjustment menu appears on the monitor.

** SYNC **

 

H PHASE

 

 

........I

 

 

-

+

SC COARSE

1(1--4)

 

SC FINE

....I....

 

-

+

RET END

5.Supply the video output signal of the camera to be adjusted and the reference gen-lock input signal to a dual-trace oscilloscope.

6.Set the oscilloscope to the horizontal rate and expand the horizontal sync portion on the oscillo- scope.

7.Move the cursor to H PHASE.

-29-