• Supply voltage:
• Recommended sensitivity of microphone:
Recommended microphone:

z Connect the microphone/line input cable and the microphone (for use of the audio reception

function).

 

Input impedance:

2 kΩ±10 %

Recommended cable length: Less than 1 m {3.3 feet} (for microphone input) Less than 10 m {33 feet} (for line input) Plug-in power type microphone (option) Connect a monaural mini plug (ø3.5 mm).

2.5 V ±0.5 V

−48 dB ±3 dB (0 dB=1 V/Pa,1 kHz)

IMPORTANT:

Connect/disconnect the external speaker cables or audio/video cables after turning off the power of the camera and the amplifier. Otherwise, loud noise may come out from the speaker.

xConnect an external amplifier-embedded speaker to the audio output cable (for use of the audio transmission function).

Connect a stereo mini plug (ø3.5 mm) (Audio output is monaural.).

Recommended cable length: 10 m {33 feet} or less

c Connect the alarm input/output cable.

<Ratings>

Terminal name

Ratings

 

 

 

ALARM OUT, AUX OUT

Open collector output (maximum applied voltage: 20 V DC)

 

 

 

 

Open

4 V DC - 5 V DC by internal pull-up

 

 

 

 

Close

Output voltage 1 V DC or less (50 mA or less)

 

 

ALARM IN

Non-voltage make contact input (4 V DC - 5 V DC, internally pulled

 

 

up)

 

 

 

 

Off

Open or 4 V DC - 5 V DC

 

 

 

 

On

Make contact with GND (required drive current: 1 mA or more)

 

 

 

Note:

Check if rating of an external device such as a sensor is applicable to the rating of this product by referring to the provided operating instructions.

Speci￿cation of 4P alarm cable (accessory)

GND (black)

ALARM IN3, AUX OUT (gray) (Terminal 3)

ALARM IN2, ALARM OUT (red) (Terminal 2)

ALARM IN1 (green) (Terminal 1)

26

Page 26
Image 26
Panasonic WV-SW458E, WV-SW458ME installation instructions Ratings Terminal name, Alarm OUT, AUX OUT