Paradyne 7510 DSU manual Device Messages 2 What Message Indicates What To Do

Models: 7510 DSU

1 69
Download 69 pages 61.65 Kb
Page 44
Image 44

Messages and Troubleshooting

Table 6-1. Device Messages (2 of 2)

Device Message

What Message Indicates

What To Do

 

 

 

Invalid Test

A loopback or 511 pattern

H Wait until other test ends and

Combination

test was in progress when

message clears.

 

Start was selected to start

H Abort all tests from the Test

 

another test, or was active

 

menu screen.

 

on the same or another

 

 

 

interface when Start was

H Stop the test from the same

 

selected.

screen the test was started

 

 

from.

 

 

 

Please Wait

Command takes longer

Wait until message clears.

 

than 5 seconds.

 

 

 

 

Test Active

A test is running and no

H Contact service provider if test

 

higher priority health and

initiated by the network.

 

status messages exist.

H Wait until the other test ends

 

 

 

 

and message clears.

 

 

H Cancel all tests from the Test

 

 

screen.

 

 

H Stop the test from the same

 

 

screen the test was started

 

 

from.

 

 

 

6-2

November 1997

7510-A2-GB20-10