Testing

Running Network Tests

Network tests require the participation of your network service provider. To access the Network Tests screen, follow this menu selection sequence:

Main Menu Test Network Tests

main/test/network

 

 

 

 

 

Device Name:

 

 

 

Model: 7510

 

 

 

NETWORK TESTS

 

 

 

 

Test

Command

Status

Result

 

 

 

CSU Loopback:

Start

Inactive

0:00:00

 

 

 

DSU Loopback:

Start

Inactive

0:00:00

 

 

 

Send V.54 Up:

Send

Sending

 

 

 

 

Send V.54 Down:

Send

Inactive

 

 

 

 

Send 511:

Start

Inactive

0:00:00

 

 

 

Monitor 511:

Stop

Active

125:08:48

Errors 99999+

±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±È±±±±±±±±±±±±±±±±±±±±±±±±±±±±±

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit ResetMon

Use the Command column to start or stop a test by pressing Enter. The Result column displays the test duration since the last device reset. When the Monitor 511 test is active, ResetMon is available to reset the error counter to zero.

7510-A2-GB20-10

November 1997

5-3

Page 35
Image 35
Paradyne 7510 DSU manual Running Network Tests, Main Menu → Test → Network Tests