C1629M-F (3/08) 29
Figure 24. RJ-45 Pin Assignments to CM9760-CDU-T
3. Connect the other end of the STRAIGHT cable to the IN connector on the CM9760-CDU-T.
4. To connect a second or third CDU:
a. Use the REVERSE cable that is included with the additional CDU.
b. Connect either end of the REVERSE cable to the OUT connector on the first CDU.
c. Connect the other end of the REVERSE cable to the IN connector on the second CDU.
d. Repeat these steps to connect the second CDU to the third CDU.
5. Use the WS5000 Endura workstation to enable each PTZ device on its specific video input.
POWERING UP THE DVR5300 SYSTEM
After you have connected all DVR5300 system components, power up the DVR5300 system:
1. Power up the ENC5300 units (refer to the ENC5300 Installation manual for more information).
2. Power up the CM9760-CDU-Ts if necessary (refer to the CM9760-CDU-T Installation/Operation manual for more information).
3. Power up the DVR5300 (refer to Unit Startup on page31).
Table C. RJ-45 Pin Assignments to CM9760-CDU-T
DVR5300 CM9760-CDU-T
Pin Lead Pin Lead
1 RX+ …connects to… 1 TX+
2 RX- …connects to… 2 TX-
3-6 Reserved 3-6 Reserved
7 TX- …connects to… 7 RX-
8 TX+ …connects to… 8 RX+
TX- TX+
RX+ RX-
TX+ TX- RX- RX+
DVR5300 CM9760-CDU-T
PIN
8PIN
1
PIN
8PIN
1