NOTE: If a preset is set when the system is at the upper tilt limit, the preset label will be overridden by the label “Tilt Limit.” The preset labels feature will not function.
NOTE: For AMERICAN DYNAMICS controllers with only 32 presets, set switch
99 becomes 32
98 becomes 31
97 becomes 30
96 becomes 29
95 becomes 28
93 becomes 26
92 becomes 25
91 becomes 24
90 becomes 23
If the limit stops are turned off (refer to the Limit Stops section), presets
NOTE: In the operation and programming instructions, sometimes a number in parentheses follows a preset. This second number is for
PAN, SCAN, AND TILT SPEEDS
Pan and scan speeds are adjustable from 3 to 40 degrees per second through the pro- gramming menu. The tilt speed is
LENS FUNCTIONS
Lens zoom, focus, and iris functions are operated from the controller. All lens models have motorized zoom and focus, and
PRESET FUNCTIONS
The Esprit system is capable of going to 64 preset locations, each with a
If you command the pan and tilt to go to an undefined preset, erratic operation may result.
Presets 33 and 34 are fixed commands, meaning that you cannot program them. Preset 33 is the “flip” command, which pans the system 180 degrees. Preset 34 is the “pan zero” com- mand, which pans the system to the
RANDOM, FRAME, AND AUTO SCANNING
Select preset 97 (30) to start random scanning. Select preset 98 (31) to activate frame scanning (three seconds of scanning followed by a
(32)to start auto (continuous) scanning. Scan limit stops are controlled by software. Refer to the Limit Stops section to program the scan limit stops.
When the system reaches a scan limit stop, it reverses direction. Select preset 96 (29) to stop a scan. Any pan and tilt or lens command also will stop a scan.
ZONES
A zone is a programmed pan area with set boundaries and identifying label. The Esprit system has a maximum of eight zones, each with a
PATTERNS
The Esprit system can do either one full pattern (1.5, 3, or 6 minutes long) or two half pat- terns (.75, 1.5, or 3 minutes long). This pattern can consist of any standard pan and tilt or lens command. Presets, flip and turbo are not allowed in a pattern. Zones can be enabled while running a pattern. Refer to the documentation for your control system to program and run patterns.
PARK
If the Esprit system does not receive any commands for a specified period of time (refer to the Park Time Minutes section), the system will go to preset 1 and park. If the time specified is zero, or if preset 1 has not been programmed, the system will not park.
Pelco Manual | 15 |