APPENDIX

NOTE: Esprit will sense and automatically select input from Coaxitron control signals in either the standard or extended mode. Therefore, the DIP switches settings have no effect on Coaxitron control signals.

Table A. Switch Settings for SW1

Baud Rate

 

Switch Setting

 

 

SW1-1

 

SW1-2

SW1-3

2400

OFF

 

OFF

 

OFF*

4800

ON

 

OFF

 

OFF*

9600

OFF

 

ON

 

OFF*

* SW1-3 is not used; set it in the OFF position.

 

 

 

 

Switch Setting

 

 

 

SW1-4

SW1-5

SW1-6

SW1-7

SW1-8

 

OFF*

Note (1)

Note (2)

Note (3)

Note (4)

 

 

 

 

 

 

NOTES:

 

 

 

 

 

(1)

SW1-5

OFF

- For controllers that have more than 32 presets.

 

 

 

ON

- For American Dynamics controllers (32 presets).

(2)

SW1-6

OFF

- For all control systems except CM9502 with variable

 

 

 

speed keyboards. For CM9502 with fixed speed keyboards,

 

 

 

set switch OFF.

 

 

 

 

ON

- For CM9502 with variable speed keyboards to get

 

 

 

smoother joystick control.

 

 

(3)

SW1-7

OFF

- RS-422 transmitter is not terminated.

 

 

 

ON

- RS-422 transmitter is terminated.

 

(4)

SW1-8

OFF

- RS-422 receiver is not terminated.

 

 

 

ON

- RS-422 receiver is terminated.

 

 

 

 

 

 

 

 

 

* SW1-4 is not used; set it in the OFF position.