NOTE: Programming preset 90 (23) disables the manual limit stops until preset 91
(24)is set. Preset 90 (23) is the left manual limit and preset 91 (24) is the right manual limit.
LIMIT STOPS
TURNING LIMIT STOPS ON OR OFF
To change the limit stop mode:
1.Program preset 95 (28). The main menu appears.
2.Position the cursor (>) beside Limits.
3.Press the Iris Open button to enter the Limits menu.
4.Position the cursor (>) beside Limit Stops.
5.Press the Iris Open button. The cursor moves to the right beside the word On or Off.
6.Move the joystick up or down to toggle between On and Off.
7.SELECT - Press the Iris Open button on your keyboard to select your choice. CANCEL - Press the Iris Close button if you do not want to change the setting.
PROGRAMMING LIMIT STOPS
Manual Limit Stops
When manual limit stops are set, pan operation (using a joystick or pan/tilt keys) stops when a limit stop is reached. The manual limit stops can be set in one of two ways:
At the controller by programming presets 90 (23) and 91 (24) or
At the controller by programming the Limit Stops menu
PRESETS
Refer to the documentation for your control system for programming presets, and then do the following:
1.Make sure limit stops are turned ON, and then exit the menu.
2.Push the joystick left until you reach the limit you want the camera to go to on the left.
3.Program preset 90 (23).
4.Push the joystick right to the limit you want the camera to go to on the right.
5.Program preset 91 (24).
Setting presets 90 (23) and 91 (24) to the same point disables manual limit stops.
LIMIT STOPS MENU
The manual pan limit stops can be set at the controller from the Limit Stops menu:
1.Program preset 95 (28). The main menu appears.
2.Position the cursor (>) beside Limits.
3.Press the Iris Open button to enter the Limits menu.
4.Move the cursor to Set Man Limits and press the Iris Open button. PRESS IRIS OPEN TO SET LEFT LIMIT appears.
5.Move the pan and tilt to the desired left limit position and press the Iris Open button to set the left manual limit. PRESS IRIS OPEN TO SET RIGHT LIMIT appears.
6.Move the pan and tilt to the desired right limit position and press the Iris Open button to set the right manual limit.
7.Exit the Limit Stops menu.
CLEAR MANUAL STOPS
To clear the manual limit stops:
1.Program preset 95 (28). The main menu appears.
2.Position the cursor (>) beside Limits.
3.Press the Iris Open button to enter the Limits menu.
4.Move the cursor to Clear Man Limits and press the Iris Open button. The cursor changes to an asterisk (*) briefly to indicate the limits have been disabled.