Pelco es3012 installation manual Speed Profile

Models: es3012

1 40
Download 40 pages 8.43 Kb
Page 28
Image 28
SPEED PROFILE

SPEED PROFILE

This feature allows the operator to set the wind speed conditions for the location of the system. You can set two wind speed profiles of 50 mph or 90 mph in which the system will remain operational. In both settings, the pan speed will be a maximum of 40 degrees per second. The difference will be in the turbo and preset pan speeds. The turbo and preset pan speeds are 100 degrees per second in the 50 mph wind profile setting and 60 degrees per second in the 90 mph profile.

To set the speed profile:

1.Program preset 95 (28). The main menu appears.

2.Position the cursor (>) beside Other.

3.Press the Iris Open button to enter the entitled Other menu.

4.Position the cursor (>) beside Spd Profile.

5.Press the Iris Open button. The cursor moves to the right, beside the wind speed (50 mph wind or 90 mph wind).

6.Move the joystick up or down to toggle through the wind speeds (50 mph wind or 90 mph wind).

7.SELECT - Press the Iris Open button on your keyboard to select your choice. CANCEL - Press the Iris Close button if you do not want to change the setting.

28

Pelco Manual C306M-K (4/05)

Page 28
Image 28
Pelco es3012 installation manual Speed Profile