SPECIFICATIONS

ELECTRICAL

 

Input Voltage:

24 or 120/230 VAC, 50/60 Hz; on ES3012-5 models, a switch is

 

installed on the transformer module located in the mount base to

 

make 120 or 230 VAC input voltage selection. Reset feature

 

enabled when power becomes unstable or interrupted.

Power Requirements:

Maximum power consumption is 70 VA per system

Heater and Defroster:

Thermostatically controlled heater consumes 10 watts and cycles

 

on at 70°F (21°C) and off at 85°F (29°C); the window defroster runs

 

continuously and consumes 2.5 watts.

Electrical Connections:

Two power source connections made at the mount location with

 

wire nut splices and one ground terminal; one BNC connector and

 

four terminals on the interconnect PCB at the mount location.

MECHANICAL

 

Construction:

Die-cast, extruded and sheet aluminum; stainless steel hardware

Finish:

Gray polyester powder coat, anodized

Viewing Window:

0.18-inch (4.76 mm) thick, optically clear impact-resistant MR5

 

coated Lexan® (U.L. 94HB rated)

Window Viewing Area:

2-inch (5 cm) diameter

Esprit System Mounting: Three 10-32 stainless-steel screws and washers (supplied) to attach the Esprit system to the EWM wall mount; three 10-32 stainless- steel nuts and washers (supplied) to attach the Esprit system to the EPA pedestal adapter

Enclosure Camera Mounting

(Non-ImagePak models): Elongated holes on removable camera mount; supplied with a camera mount adapter to accommodate various heights of cameras

Maximum Camera and Lens Size (Non-ImagePak models):

Latches:

Accepts 24 VAC camera and lens combinations (including BNC connector) up to 2.87 (W) x 3.15 (H) x 12.10 (L) inches

(7.28 x 8.00 x 30.73 cm)

One link-lock, No. 3 stainless steel latch; can be secured with padlock (not supplied)

GENERAL

 

Environment:

• Indoor/outdoor

 

• Capable of continuous-duty operation

 

• Temperature range -40°to 122°F (-40°to 50°C)

 

• Operating temperature range -40°F (-40°C) to 122°F (50°C) for

 

sustained system operation or 140°F (60°C) absolute maximum

 

• Will remain operational in 90 mph wind conditions

Ratings:

IP 66

 

NEMA 4X

Dimensions:

See Figure 1

Weight

 

ES3012-2/-5:

20.0 lb (9.1 kg)

ES3012-2N/-5N:

20.6 lb (9.3 kg)

ES3000 Series

 

(ImagePak):

25.7 lb (11.7 kg)

(Design and product specifications subject to change without notice.)

36

Pelco Manual C306M-K (4/05)

Page 36
Image 36
Pelco es3012 installation manual Specifications, Electrical