C3432M-G (4/09) 17
ALARM AND 24 VAC WIRES

CONNECTING A RELAY DEVICE

The IP110 Camclosure has an output for triggering an external device. It supports both momentary and
continuous relay operation.
You can operate the relay interactively, during an active connection, or automatically to coincide with
certain events. Typical applications include activating a door, gate or lock, or switching on lights or other
electrical devices.
Figure 10. Relay Wiring
Figure 10 shows how to wire the relay with its power source to the Camclosure.
NOTE: The green/white wire is internally connected to the Camclosure chassis. Any connected signaling
device should remain floating with respect to the Camclosure chassis; otherwise damage could result.
Table B. Wire Descriptions
Wire Color Description
Black 24 VAC (use only if PoE is not connected)
Red 24 VAC (use only if PoE is not connected)
Blue Alarm In
Blue/White Alarm In, Return
Green Relay Out
Green/White Relay Out, Return
WARNING: Do not exceed the maximum rating of 12 VDC, 0.15 A.
+
_
DC

CONNECTING A RELAY DEVICE

(CONNECTION EXAMPLE)
GREEN WIRE
GREEN / WHITE WIRE