ALARM AND 24 VAC WIRES
| Table B. Wire Descriptions |
|
|
Wire Color | Description |
|
|
Black | 24 VAC (use only if PoE is not connected) |
|
|
Red | 24 VAC (use only if PoE is not connected) |
|
|
Blue | Alarm In |
|
|
Blue/White | Alarm In, Return |
|
|
Green | Relay Out |
|
|
Green/White | Relay Out, Return |
|
|
CONNECTING A RELAY DEVICE
The IP110 Camclosure has an output for triggering an external device. It supports both momentary and continuous relay operation.
You can operate the relay interactively, during an active connection, or automatically to coincide with certain events. Typical applications include activating a door, gate or lock, or switching on lights or other electrical devices.
WARNING: Do not exceed the maximum rating of 12 VDC, 0.15 A.
Figure 10 shows how to wire the relay with its power source to the Camclosure.
CONNECTING A RELAY DEVICE
(CONNECTION EXAMPLE)
DC
GREEN WIRE
GREEN / WHITE WIRE
_ +
Figure 10. Relay Wiring
NOTE: The green/white wire is internally connected to the Camclosure chassis. Any connected signaling device should remain floating with respect to the Camclosure chassis; otherwise damage could result.
17 |