DW/CW SERIES (WIDE DYNAMIC RANGE) ADJUSTMENTS
Refer to Figure 19 to adjust the IP110-DW or IP110-CW model.
SW1
DEFAULT SWITCH POSITION
R7
Figure 19. Adjusting the IP110-DW/CW Series Camclosure
SWITCH SETTINGS
Locate the DIP switch. Then set the switches for your installation.
Set
SW1-2: N/A
SW1-3: Interlaced Scanning/Progressive Scanning
Interlaced scanning is the standard for analog recording installations. Each frame contains one odd and one even field, each processed separately.
Progressive scanning is better for digital recording installations. Each frame is processed as a whole, which results in less blurring and cleaner digital conversion. It also saves storage space on digital video recorders.
Set
Set it to OFF to select progressive scanning. The default setting is ON.
27 |