Camera Adjustments
To perform camera adjustments:
1.Make sure the camera and service connectors are connected to the board inside the back box. You may have to remove the camera module from the back box.
2.Connect a monitor to the service connector (refer to Service Connector on page 32). Turn on the monitor.
3.Turn on the camera. The camera will start the following configuration process:
•The green LED inside the back box flashes five times per second for approximately two minutes, or until the PC or server recognizes the mini dome.
•If the dome is not connected to a Dynamic Host Configuration Protocol (DHCP) PC/server, the green LED will flash for approximately four minutes before the camera switches to an automated private IP addressing mode.
NOTE: If the IP110 is connected to a DHCP network, the server will automatically assign an IP address to the camera. If the IP110 is connected to static network, the IP address 192.168.0.20 on netmask 255.255.255.0 is automatically assigned to the camera. If the camera has an older software version installed (versions 01.00.0038 and older for IP110 and versions 01.00.0018 for IP3701H), the network will automatically cycle through the IP address range of 169.254.200.0 through 169.254.200.255, on netmask 255.255.255.0. The first available address located will be assigned to the IP110. If the network cannot find an open address in the default range, contact your network administrator.
4.To adjust the camera, you will need a miniature trimpot adjustment tool with a
5.Refer to the following sections for detailed information on camera adjustments:
•Varifocal Lens Zoom and Focus Adjustments on page 22
•DN/CH Series Adjustments on page 24
•DW/CW Series (Wide Dynamic Range) Adjustments on page 27
6.After you have adjusted the unit, reinstall the camera module into the back box, and then install the trim ring, bubble, and dome liner (refer to page 31).
21 |