Click suppression in combination for any module

 

-

for audio switching

: > 60 dB

-

for power on/off switching

: > 30 dB

-

mute by on/off switch

: > 80 dB

 

 

Pilot tone 20 kHz sinus asymmetrical

 

-

volume preset at least

: 0.05 - 1 V

-

mute by on/off switch

: > 80 dB

 

 

CRM Output relays

 

-

A.C. switching

: 32 V @ 2 Amps

-

D.C. switching

: 48 V @ 2 Amps

 

 

MAINS SUPPLY

 

-

voltage setting at delivery

: 220-230 V

-

mains voltage selection range

: 110 V, 127 V, 220-230 V or 240 V

-maximum voltage deviation:

 

for all selected ranges

: +10 /-10%

 

however at 230 V mains

: + 6 /-10%

-

mains frequency

: 50 - 60 Hz

-

power consumption at mains voltage

: < 90 VA

-

mains fuse: at 220/240 Volt

: T2.5 A

-

at 110/127 Volt

T5 A

-mains transformer:

 

temperature switch self restoring type

: +125 °C

 

 

EMERGENCY SUPPLY

 

The unit can be supplied from an external DC voltage

 

-

V DC nominal

: 48 V @ current: < 1.2 A

 

V DC minimum

: 42 V @ current: < 1.2 A

 

V DC maximum

: 58 V @ current: < 1.2 A

-fuse in 48 V DC line on PCB located in housing

-polarity protection against reverse connection

MECHANICAL DATA

-dimensions:

 

19” rack mounting

: 483 x 310 x 132 mm

 

desktop use

: 440 x 310 x 132 mm

-

weight LBB 1280

: 8.8 kg (unpacked)

 

 

ENVIRONMENTAL REQUIREMENTS

 

Rated range of use

 

-

ambient temperature

: -10 to +45 °C

-

relative humidity

: 15 - 90%

Climatic conditions during transporting handling and storage

-

according to

: UN-D 1639/01

-

temperature

: -40 to +70 °C

-

relative humidity

: 5 - 95%

45