User’s Manual of
The page includes the following fields:
|
|
|
|
|
|
Object | Description | ||||
PoE PSU Status | PoE PSU Status shows status of power supply for PoE output. | ||||
|
|
|
| ||
|
|
|
|
| |
PoE Temperature Unit 1 | Display the current operating temperature of PoE chip unit 1. | ||||
|
|
|
| ||
|
| The unit 1 is in charge of PoE | |||
|
|
|
|
| |
PoE Temperature Unit 2 | Display the current operating temperature of PoE chip unit 2. | ||||
|
|
|
| ||
|
| The unit 1 is in charge of PoE | |||
|
|
|
|
| |
Power limit mode | Allow to configure power limit mode of Web Smart Device. It can choose : | ||||
|
| | Port Priority Deliver PoE power by port priority setting | ||
|
| | Total Limit. Set limit value of the total POE port provided power to the PDs. | ||
|
|
|
|
| |
Power Allocation | Show the total watts usage of PoE Switch. | ||||
|
|
|
|
| |
PoE Function | Can enable or disable the PoE function. | ||||
|
|
|
|
| |
Priority | Set port priority for the POE power management | ||||
|
| It can choose the “port priority”, value is : | |||
|
| | Critical | ||
|
| | High | ||
|
| | Low | ||
|
| High priority is “Critical”. | |||
|
|
|
|
| |
Device class | Class 0 is the default for PDs. However, to improve power management at the | ||||
|
| PSE, the PD may opt to provide a signature for Class 1 to 3. | |||
|
| The PD is classified based on power. The classification of the PD is the maximum | |||
|
| power that the PD will draw across all input voltages and operational modes. A | |||
|
| PD shall return Class 0 to 3 in accordance with the maximum power draw as | |||
|
| specified by Table 4.1. | |||
|
|
|
|
| |
Current(mA) | It shows the PoE device current Amp. | ||||
|
|
|
|
| |
Consumption [W] | It shows the PoE device current watt. | ||||
|
|
|
|
| |
Power Limit | It can limit the port PoE supply watts. | ||||
|
| Per port maximum value must less 15.4, total ports values must less than the | |||
|
| Power Reservation value. | |||
|
| Once power overload detected, the port will auto shut down and keep on | |||
|
| detection mode until PD’s power consumption lower than the power limit value. | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
For
122