Connect five or more SpectraLink 8000 Telephony

SpectraLink 8000 Telephony Gateway Administration Guide

When installing a system with four or fewer SpectraLink 8000 Telephony Gateways and a SpectraLink 8000 SVP Server, no IPC cables are required. For this configuration, follow the directions for connecting five or more SpectraLink 8000 Telephony Gateways.

Connect five or more SpectraLink 8000 Telephony

Gateways

To mount five or more SpectraLink 8000 Telephony Gateways:

1.Mount the SpectraLink 8000 Telephony Gateways on the backboard or rack.

2.No IPC cable connection is required for five or more SpectraLink 8000 Telephony Gateways. Simply connect each SpectraLink 8000 Telephony Gateway to the local area network via an Ethernet Switch per Connect SpectraLink 8000 Telephony Gateway to LAN below.

3.This system configuration requires a SpectraLink 8000 SVP Server. See the document SpectraLink 8000 SVP Server Administration Guide for SRP.

Connect SpectraLink 8000 Telephony Gateway to Demarc Blocks

Connect the male RJ-21 connector from the appropriate demarcation block to the designated RJ-21 connector (A or B) on each SpectraLink 8000 Telephony Gateway. Secure the cables using the keeper.

Connect SpectraLink 8000 Telephony Gateway to LAN

Each Gateway requires a separate Ethernet connection on an Ethernet switch. Using an RJ-45 cable, connect the NETWORK port on each SpectraLink 8000 Telephony Gateway to the connecting port on the same Ethernet switch.

Connect power

1.Once the units have been properly grounded, connect the power plug from the AC adapter to the jack labeled PWR on the SpectraLink 8000 Telephony Gateway.

36

PN: 1725-36028-001_T.doc

Page 36
Image 36
Polycom 1725-36028-001 manual Connect five or more SpectraLink 8000 Telephony Gateways, Connect power