Configure modem internal settings (US Robotics Sportster)

SpectraLink 8000 Telephony Gateway Administration Guide

The following settings use the US Robotics® Sportster® modem. Other modem models may be used, but the particular model’s settings will have to be adapted to conform to those listed in the following table.

Configure modem internal settings (US Robotics Sportster)

1.

Connect the modem to a PC using a standard modem cable. Plug

 

the 9-pin connector into the RS-232 port on the PC, and the 25-pin

 

connector into the modem’s port.

2.

Using a standard communications package such as ProComm

 

Plus or HyperTerminal™, bring up the modem and type the

 

following commands. Press Enter after typing each command.

 

 

 

Command

Description

 

AT&F1

Loads factory default settings

 

AT&H0

Sets Transmit Data Flow control to disabled

 

 

 

 

AT&R1

Sets modem to ignore Request to Send (RTS)

 

AT&W0

Saves the configuration

 

 

 

 

 

3.

Power off the modem, and then turn it back on.

4.

Type: ATI4 and press Enter. The settings should match those

 

shown in the following figure, which was taken from ProComm

 

Plus.

 

 

50