Polycom 1725-36028-001 manual Press Esc to return to the NetLink Wireless Telephone System menu

Models: 1725-36028-001

1 110
Download 110 pages 42.86 Kb
Page 64
Image 64
Press Esc to return to the NetLink Wireless Telephone System menu.

SpectraLink 8000 Telephony Gateway Administration Guide

The SpectraLink 8000 Telephony Gateway monitors the condition of any SpectraLink 8000 SVP Server(s) on the system. In a single SpectraLink 8000 SVP Server system, when the SVP Server goes into Maintenance Lock, the Telephony Gateway will also lock and set an alarm. No new calls will be allowed but calls in progress will not be affected.

In multiple SVP Server systems, when one SVP Server goes into Maintenance Lock, it sends a message to the Telephony Gateway(s) which will stop using the locked SVP Server. It may take up to 30 seconds for the message to reach the Telephony Gateway. If all SVP Servers lock, then the Telephony Gateway will also lock and set an alarm. No new calls will be allowed but calls in progress will not be affected.

Checkout all phones: If the TFTP server is on a PC, this command is used to upgrade each handset without having to reset the Gateway. This command forces all the handsets on the system to check in with the Gateway. They will check their current software version vs. the version stored on the TFTP server and download if needed. Any handsets in a call will perform their checkout after the call is complete.

Reset System: If this option is selected, you will be prompted to reset this SpectraLink 8000 Telephony Gateway.

Reset All Systems: If this option is selected, you will be prompted to reset all SpectraLink 8000 Telephony Gateways.

Press Esc to return to the NetLink Wireless Telephone System menu.

64

PN: 1725-36028-001_T.doc

Page 64
Image 64
Polycom 1725-36028-001 manual Press Esc to return to the NetLink Wireless Telephone System menu