The name of this command is an abbreviation of "Global Mute Outputs." Enabling this option causes all of the physical outputs to be muted (outputs 1, A, B, T) . This muting is independent of the normal output mute command, MUTEO. This command is provided so that the control program can implement

a "saftey mute" feature. The idea is that if the user accidentally misconfigures the Vortex and feedback begins to occur, they can press the saftey mute to instantly mute all outputs before they damage their equipment or ears.

This command is a boolean command. See Section 6.1 for more information on this type of command.

This command is saved to non-volatile memory only as part of a preset. The state of this command will be restored after power-up only if a preset is saved and that preset is set to be the power-on preset.

Example

Description

Status Message

S01GMUTEO1

Enable global output mute.

S01GMUTEO1

S01GMUTEO0 Disable global output mute.

S01GMUTEO0

 

 

S01GMUTEOx , where x is 0 or 1 depending on the

S01GMUTEO2 Toggle global output mute.

current state of the global output mute.

 

S01GMUTEO? Query acknowledgement mode. S01GMUTEOx , where x is 0 or 1 depending on the current state of the global output mute.

8.66. ID -- Set Device ID

This command sets or queries the Device ID for the Vortex. Typically, the device ID is set from the front panel of the Vortex, so this command is not normally used. There are restrictions involving having devices with the same ID linked on EF Bus -- see the Vortex Reference Manual for more details.

This command is an integer command. See Section 6.2 for more information on this type of command. The minimum and maximum values for this command are 0 and 7, respectively.

This command is saved to global non-volatile memory and is not part of a preset. Its value is saved each time it is changed. It will retain its value after power-down. Since this command writes to non- volatile memory, there will be a delay before an acknowledgment is returned.

Example

Description

Status Message

S01ID3

Change the device ID from 1 to 3

S03ID3

S01ID?

Query current device ID.

S01ID1

8.67. LABEL -- Set or Query one of the Device Labels

This command sets or queries one of the many labels stored in the device. The LABEL command has the following syntax:

Page 64
Image 64
Polycom RS-232 manual ID -- Set Device ID, Label -- Set or Query one of the Device Labels

RS-232 specifications

Polycom RS-232 is a key interface utilized in various communication and audiovisual systems, enabling effective integration between different devices. This technology employs a standard serial communication protocol that allows for robust control and communication, particularly in environments that require sophisticated audiovisual setups.

One of the main features of Polycom RS-232 is its ability to facilitate point-to-point communication over distances of up to 50 feet without the need for a repeater. This long-range connectivity is essential in large conference rooms and auditoriums where devices are often spread out over considerable distances. The serial connection is often more reliable than wireless options, which can be susceptible to interference.

Another notable characteristic is its versatile compatibility with a range of devices, including cameras, projectors, and interface panels. This allows users to control multiple devices from a single point, streamlining the operation of complex setups. The straightforward nature of RS-232 commands simplifies integration, which is a significant benefit for both installers and end-users.

Polycom RS-232 also supports various baud rates, giving users the flexibility to optimize communication speed based on their requirements. This adaptability ensures that users can achieve the desired performance, whether they are managing basic functions like power and volume control or more complex commands for switching video sources or adjusting settings.

The technology also features error-checking capabilities, which contribute to its reliability in communication. This reduces the likelihood of issues during operations, ensuring that commands are correctly received and executed. Additionally, its structured protocol aids in diagnosing and troubleshooting, making it easier to manage any issues that arise.

With its robust nature and proven reliability, Polycom RS-232 remains a pivotal technology in the realm of audiovisual communications. Its combination of long-range capabilities, compatibility, flexibility, and reliability makes it an essential tool for enhancing the efficiency of modern communication environments. As technology continues to evolve, the importance of dependable interfaces like Polycom RS-232 cannot be overstated, ensuring seamless integration and operation of sophisticated communication systems. Whether used in educational institutions, corporate environments, or event venues, Polycom RS-232 guarantees a streamlined experience in device management and control.