Polycom RS-232 manual LID -- Assign Action for when Logic Input is Deactivated, Assign the command

Models: RS-232

1 123
Download 123 pages 19.08 Kb
Page 71
Image 71

S01LIA4,MUTEI11

S01LIA5,MACROX23

S01LIA6,BROADA:S02MUTEI11

S01LIA7,

Assign the command MUTEI11 to occur when logic input pin 4 changes from the inactive to active state. The MUTEI11 mutes input channel 1

Assign the command MACROX23 to occur when logic input pin 5 changes from the inactive state to the active state. The MACROX23 command executes macro 23, which can contain up to 256 other commands.

Assign the command

BROADA:S02MUTEI11 to

occur when logic input pin 6 changes from the inactive state to the active state. This command causes the EF2211 at ID 2 to mute its input channel

1 when logic pin 6 on the EF2211 at ID 1 changes from the inactive to active state.

Assign a blank command to occur when logic input pin 7 changes from the inactive state to the active state. Assigning a blank command means no action will take place as a result of this state change.

S01LIA4,MUTEI11

S01LIA5,MACROX23

S01LIA6,BROADA:S02MUTEI11

S01LIA7,

S01LIA4,<string> , where

<string> is the command string that

Query the command

S01LIA4,?associated with the active state of logic pin 4.

will be executed when logic input 4 is activated. If this query was given after the example for logic input 4 above, the response would be

S01LIA4,MUTEI11 .

8.77.LID -- Assign Action for when Logic Input is Deactivated

Page 71
Image 71
Polycom RS-232 manual LID -- Assign Action for when Logic Input is Deactivated, Assign the command