Printek FormsMaster 8000se Series manual Emulations, Select Software Interface n, ESC ESC n

Models: PrintMaster 850 Series FormsPro 4000se Series FormsMaster 8000se Series

1 166
Download 166 pages 48.2 Kb
Page 113
Image 113
Manual background

Printek Emulation

Emulations

Select Software Interface n

ESC ESC n

Selects the software interface n according to the table below.

nSoftware Interface

0Test (reserved for factory use)

1ANSI X3.64 Emulation

2Epson FX Emulation

3Bar Code Mode (optional)

4IBM Proprinter Emulation

5DEC LA120 Emulation

6TTY Emulation

7Printek Emulation

;Remote Setup Mode

<Genicom 3840

=Genicom 3410

?Previously Selected Emulation

?Previously Selected Emulation

@Default Emulation

Overrides the “Emulation” value in the interface setup menu.

A numeric value for n may be specified in two different ways, with equivalent results: a single byte with a value of 00 to 07 hex, or a single printable ASCII character “0” to “7” (30 to 37 hex).

If more than one emulation has been selected, ESC ESC ? will return to the previously selected emulation. This is particularly useful when the previous emulation is unknown. Please beware that the memory (stack) is only one level deep.

ESC ESC @ will return to the default emulation, as specified by the “Emulation” value in the interface setup menu.

This chapter describes Printek emulation. If a different interface is selected, the control codes and escape sequences described in this chapter will no longer be applicable.

Example: The following escape sequences will select Printek emulation, load form one, and then return to the previous emulation.

Escape Sequence:

ESC

ESC

7

ESC

L

1

ESC

ESC

?

Hexadecimal:

1B

1B

07

1B

4C

01

1B

1B

3F

107

Page 113