ANSI X3.64 Emulation

Set Horizontal Tab Stops

ESC D n1 n2 ... nx NUL

Clears all currently set horizontal tab stops, and sets new tab stops at column n1, n2, n3, etc. 1³n³255. The tab stops must be presented in ascending order. The NUL character, or any tab stop value less than the preceding one, terminates the sequence. The tab stops are set relative to the current character spacing, but subsequent changes in character spacing will not affect the physical position of the tab stops (except that the position will be rounded up to the closest character boundary). The leftmost column is column zero.

Default tab stops are set at every eighth column, i.e. column 8, 16, 24, 32, 40, etc. The tab stops set by ESC D will replace the default tab stops. ESC D NUL will clear all tab stops, leaving no tab stops set. The default tab stops are restored by ESC @.

Example: The following escape sequence will set horizontal tab stops at half inch intervals, if character spacing is currently 10 cpi.

Escape Sequence:

ESC

D

5

10

15

20

25

30

NUL

Hexadecimal:

1B

44

05

0A

0f

14

19

1E

00

Vertical Tabs

Vertical tab stops are associated with absolute physical positions, not with lines. The tab stops are set relative to the current line spacing, but subsequent changes in line spacing will not affect the physical position of the tab stops.

Vertical Tab

VT

Causes the current line to be printed, and then advances the paper to the next vertical tab stop. If no vertical tab stops are set, then a line feed is done instead. If “Auto CR” is set to “On” in the interface setup menu, a carriage return will also be performed.

Control code:

VT

Hexadecimal:

0B

Set Vertical Tab Stops

ESC B n1 n2 ... nx NUL

Clears all currently set vertical tab stops, and sets new tab stops at line n1, n2, n3, etc. 1³n³255. The tab stops must be presented in ascending order. The NUL character, or any tab stop value less than the preceding one, terminates the sequence. The tab stop settings are based on the current line spacing. Changing the line spacing after the tab stops are set will not affect the position of the tab stops. The first line is line zero.

ESC B NUL will clear all currently set vertical tab stops, leaving no vertical tab stops set.

Example: The following escape sequence will set vertical tab stops at line 6, 12, and 24. If line spacing is currently 6 lpi, this will result in tab stops one inch, two inches, and four inches from the top of the form.

Escape Sequence:

ESC

B

6

12

24

NUL

Hexadecimal:

1B

42

06

0C

18

00

35

Page 41
Image 41
Printek FormsMaster 8000se Series, PrintMaster 850 Series manual Set Horizontal Tab Stops, Set Vertical Tab Stops

PrintMaster 850 Series, FormsPro 4000se Series, FormsMaster 8000se Series specifications

The Printek FormsPro 4000se Series, PrintMaster 850 Series, and FormsMaster 8000se Series represent the pinnacle of high-performance printing technology tailored for businesses that require reliable, efficient, and versatile printing solutions.

The Printek FormsPro 4000se Series is designed specifically for high-volume forms printing, making it an ideal choice for industries like finance, logistics, and healthcare. This series features a robust print head that allows for fast, high-quality printing of multi-part forms. One of its standout characteristics is the ability to print on a variety of media, including carbonless paper, ensuring compatibility with different business needs. The integration of advanced thermal printing technology enhances efficiency and reduces the need for frequent maintenance, allowing businesses to focus on their core operations.

In contrast, the PrintMaster 850 Series is engineered for versatility, primarily targeting businesses that require durable and reliable label printing. This series boasts a compact design without compromising on performance, making it suitable for office use or mobile applications. The PrintMaster 850 Series is equipped with advanced connectivity options, including USB and Bluetooth, which ensure seamless integration with various devices. One of its key features is the ability to print at high resolutions, delivering sharp and clear labels essential for branding and compliance purposes.

The FormsMaster 8000se Series takes heavy-duty printing to the next level. It is engineered to handle the most demanding printing tasks with remarkable precision and speed. This series incorporates innovative printing technology that ensures minimal downtime with self-cleaning mechanisms and easy-to-replace print heads. The FormsMaster 8000se is particularly favored by manufacturers and distribution centers due to its ability to print on large rolls of paper, dramatically increasing productivity. It supports multiple thicknesses and types of media, making it incredibly adaptable to various printing requirements.

In summary, the Printek FormsPro 4000se, PrintMaster 850, and FormsMaster 8000se series are unparalleled in their respective domains. The FormsPro is ideal for high-volume multi-part forms, the PrintMaster excels in label printing with portable versatility, and the FormsMaster stands out in handling large-scale industrial printing challenges. Together, these series exemplify the latest advancements in printing technology, offering businesses optimal solutions to enhance their operational efficiency.