Printek FormsPro 4000se Series manual Control Codes and Escape Sequences Grouped by Function, Null

Models: PrintMaster 850 Series FormsPro 4000se Series FormsMaster 8000se Series

1 166
Download 166 pages 48.2 Kb
Page 73
Image 73
Null

DEC LA120/210 Emulation

Control Codes and Escape Sequences

Grouped by Function

Communications

Null

NUL

This control code is ignored by the printer.

Control code:

NUL

Hexadecimal:

00

Delete

DEL

This control code is ignored by the printer.

Control code:

DEL

Hexadecimal:

7F

End of Text

ETX

If “ETX/ACK” is set to “On” in the interface setup menu, then receipt of an ETX causes the printer to transmit an ACK to the host computer.

Since the ETX may be a legal value within an escape sequence, it is the user's responsibility to ensure that an ETX used for data handshake is not sent within an escape sequence. The user must also ensure that the maximum block size or the number of blocks sent at one time does not exceed the input buffer size of the printer.

ETX/ACK handshake is available only with serial I/O.

Control code:

ETX

Hexadecimal:

03