Deactivate for
Activate for
Deactivate for
Activate for
Deactivate for
END
Code 93 Options
Minimum Label
Length
Read Verification
The Code 93 symbology has the following programmable features:
•Minimum Label Length
•Read Verification
Minimum Label Length sets the minimum label length required for Code 93 symbology. This feature causes the scanner to ignore small label segments, reducing the possibility that a portion of a good label is incorrectly seen as an entire label.
Read Verification is the number of times the scanner is required to read the bar code data before sending the label data to the host.
110 | PowerScan™ Scanner |