Beeper Settings
These labels provide options for the scanner’s audible ’beep’ signal. Reference LED and Beeper Indicators on page 11 for more information about beeper behavior.
Audible Signal - enables/disables the beep upon completion of a good read.
| It is strongly recommended that this feature |
| remain enabled, as the good read beep pro- |
| vides the best scanning status feedback to the |
NOTE | user. Error tones are always enabled and can- |
not be disabled. |
Beeper Volume - allows setting of the beeper to three different volume settings. The greatest volume occurs with frequency set high and volume set to 3.
Good Read Beeper Frequency - adjusts the pitch of the beeper to low, medium, or high.
Configuring
the Beeper
Options
Good Read Beep Duration - can be adjusted to SHORT (100msec), MEDIUM (250msec), or LONG (500msec) durations.
When to Beep - may be programmed to announce a ’good read’ upon completion of one of the following events:
•Decode of a bar code label.
•Transmission of data from the scanner to the host.
•CTS activation at the host terminal
Scan these bar codes to set the beeper options.
1.Scan the SET bar code.
2.Scan the bar code(s) for option(s) desired.
3.Scan the END bar code on page 133.
Programming Guide | 131 |