Label Length Format
Variable Length Format
Follow the steps below to set the MSI/Plessey label length format to either the Variable Length or Fixed Length format.
Follow the steps below to set the MSI/Plessey to read Variable Length Format.
1.Identify the minimum length setting you want to make. The selectable range is 04 to 16 characters.
2.Scan the SET bar code.
3.Scan the ENABLE VARIABLE LENGTH FORMAT bar code.
4.Scan the SET MINIMUM LABEL LENGTH bar code.
5.Set the minimum label length by scanning the applicable digits bar codes on page 128. Return to this page.
If you are setting a label length less than ten, you
must scan a zero digit first and then the length
digit (e.g., 04, 06, 08).
NOTE
6.Scan the END bar code.
Variable Length
SET
Enable Variable Length
Format---------
Set Minimum Label
Length---------
END
Programming Guide | 125 |