R
VOYAGEUR Wood Insert
3Maintenance and Service
A. Disposal of Ashes
•Frequency: When ash reaches the top of the brick covers (should not spill over covers). Leave 1/4 inch (6mm) of ash in the bottom of the firebox.
•By: Homeowner
WARNING! Risk of Fire! Ashes could contain hot embers.
•Place ashes in a metal container with a
•Theclosedcontainershouldbeplacedonanoncombustible fl oor or on the ground, well away from all combustible materials, pending fi nal disposal.
•If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled
Creosote - Formation and Need for Removal
•When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote.
•The creosote vapors condense in the relatively cool chimney fl ue of a
•As a result, creosote residue accumulates on the fl ue lining. When ignited this creosote makes an extremely hot fi re.
•The chimney and chimney connector shall be inspected every two months during the heating season to determine when a creosote buildup has occurred.
•When creosote has accumulated it shall be removed to reduce the risk of a chimney fi re.
B.Chimney and Chimney Connector Inspection/Cleaning
•Frequency: Every 2 months during heating season or as recommended by a certifi ed chimney sweep; more frequently if chimney exceeds or is under
•By: Certifi ed chimney sweep
•Remove all ash from the fi rebox and extinguish all hot embers before disposal.
•Allow the appliance to cool completely.
•If your type of installation involves a full reline of the chimney, it will be necessary to either remove the baffl e from the insert, or remove the insert from the fi replace and disconnect the vent prior to cleaning the chimney. Refer to page 22 in this manual for instructions on Baffl e Removal.
•If your type of installation is direct connect within a masonry chimney, the insert will need to be pulled out from the fi replace and disconnected from the fl ue prior to cleaning the chimney.
•The creosote or soot should be removed with a brush specifi cally designed for the type of chimney in use.
•Clean out fallen ashes from the fi rebox.
•It is also recommended that before each heating season the entire system be professionally inspected, cleaned and repaired if necessary.
WARNING! Risk of Fire!
Do not use chimney cleaners or fl ame colorants in your appliance. It will corrode your pipe.
C.Appliance Inspection - Routine
•Frequency: Every 2 months at the same time the chim- ney and chimney connector are inspected.
•By: Homeowner
Check for:
•Cracks in glass
•Door handle - smooth cam operation
•Baffl e and ceramic blanket correct placement
•Baffl e for warpage
•Firebrick for cracks, broken or crumbly
•Door gasket. (Dollar bill test). Place a dollar bill between the stove and the door and then shut the door. If you can pull the dollar bill out, replace the door gasket.
•Glass frame for loose screws
D. Cleaning Plated Surfaces
•Frequency: As desired
•By: Homeowner
•Clean all the fi ngerprints and oils from plated surfaces BEFORE fi ring the appliance for the fi rst time.
•If not cleaned properly before lighting your fi rst fi re, the oils can cause permanent markings on the plating.
•After the plating is cured, the oils will not affect the fi nish and little maintenance is required.
•Wipe clean as needed.
CAUTION! Do not use polishes with abrasives. It will scratch plated surfaces.
Page 18 | November 22, 2011 |