R
VOYAGEUR Wood Insert
9Appliance Set-up
Remove the zip tie to the lower access cover. It is to prevent the cover opening during shipping.
A. Outside Air Kit Installation
A source of air (oxygen) is necessary in order for combustion to take place. Whatever combustion air is consumed by the fi re must be replaced. Air is replaced via air leakage around win- dows and under doors. In homes that have tightly sealed doors and windows, an outside air source is needed. An optional Out- side Air Kit is available.
WARNING
Fire Risk.
Asphyxiation Risk.
Do not draw outside combustion air from:
•Wall, fl oor or ceiling cavity
•Enclosed space such as an attic or garage
•Close proximity to exhaust vents or chimneys
Fumes or odor may result
Items Needed for Installation (not supplied)
•4 inch fl ex aluminum pipe, or if using alternate material,
then it shall be made from durable,
•Phillips head screw driver
•Silicone sealant
WARNING
Asphyxiation Risk.
Outside air inlet must be located to prevent blockage from:
•Leaves, snow, ice or other debris Block may cause combustion air starvation
Smoke spillage may set off alarms or irritate sensitive indi- viduals.
If Not Installing the Outside Air Kit
1.Swing grille down to expose the two screws. Figure 40.1
2.Remove the two screws and pull the access assembly away from the appliance.
3.Remove the outside air cover plate A and discard.
4.
Option One - Outside Air Installation Instructions
1.Remove the outside air cover plate B on outer can and dis- card. Figure 40.2.
2.Install optional fl ex adapter to outer can with the same screws. Do not use plastic wire ties that come with the kit as they will melt. NOTE: You may need to install the fl ex pipe into the fi rebox fi rst depending on installation. Attach fl ex to adapater with at least 2 screws.
3.Ensure existing access hole in fi replace is suffi cient to feed the 4 inch fl ex.
4.After sliding can into fi replace, feed fl ex into cut opening to obtain outside combustion air.
5.Level outer can and install appliance. See page 41.
Option Two - Outside Air Installation Instructions
1.Remove the outside air cover plate B on outer can and dis- card and reuse the 4 screws.
2.Ensure existing acces hole in fi replace will not be covered by the outer can. Existing outside air intake hole may be under at the rear or side of outer can. Outside air may also enter down existing chimney chase in some situations.
3.Repeat step 5 under Option One with one exception. After installing the appliance in the outer can, seal the fi replace opening and trim package with insulation to prevent air leak- age into the room.
WARNING
Asphyxiation Risk.
Length of outside air supply duct shall NOT exceed the length of the vertical height of the exhaust fl ue.
•Fire will not burn properly
•Smoke spillage occurs when door is opened due to air starvation.
Grille hinges |
| |
downward |
| |
Remove Screws & |
| |
Pull Access Assembly | Remove Outside Cover | |
away from Insert | ||
Plate A (DISCARD) | ||
|
Figure 40.1
Outside Air Cover |
Plate B (DISCARD) |
Termination |
Cap |
Flex Adapter |
Figure 40.2
Page 40 | November 22, 2011 |