D. Blower Replacement

R

VOYAGEUR Wood Insert

D. Blower Replacement

1.The grille on the blower access assembly is hinged. Swing the grille downward to expose the 2 screws.

Figure 23.1.

2.Remove the 2 screws from the blower access assembly and slide assembly away from the appliance.

3.Disconnect the wires from the blower.

4.Remove the 2 screws from the hold down bracket and pull the blower and bracket forward.

5.Remove the blower from the hold down bracket.

6.Remove the protection guards from each end of the blower.

7.Re-install in reverse order. Be certain that the hold down bracket’s screws are completely seated in the grom- ments. Insert the locating tab in the hold down bracket into the placement slot.

Manual background CAUTION

Shock Risk.

Do NOT remove grounding prong from plug.

Plug directly into properly grounded 3 prong receptacle.

Route cord away from appliance.

Do NOT route cord under or in front of appliance.

WARNING

Fire Risk.

Do NOT allow hot coals or embers to overfl ow ash lip

May melt protective wire coating on fan power cord causing electrical short, fi re or injury

CAUTION! Unplug appliance from power source before replacing any components.

Placement Slot

Blower Access

Assembly

Grille hinges

Hold Down

downward

Bracket

 

 

 

Remove Screws and

Remove Screws &

 

Remove Both

Pull Access Assembly

Remove Screws from Hold

Protection Guards at

away from Insert

Each End

Down Bracket and Pull

 

 

Forward