F. 2-10-3 Rule

These are safety requirements and are not meant to assure proper fl ue draft.

This appliance is made with a 6 inch (152mm) diameter chimney connector as the fl ue collar on the unit.

Changing the diameter of the chimney can affect draft and cause poor performance.

It is not recommended to use offsets and elbows at altitudes above 4000 feet above sea level and or when there are other factors that affect fl ue draft.

3 ft. (91cm)

Minimum

2 ft. (61cm)

10 ft. (305cm) To Nearest Roofline

Less than 10 ft. (305cm)

2 ft. (61cm)

3 ft. (91cm)

Minimum

Pitched Roof

Figure 29.1

10 ft. (305cm) or more

Wall or Parapet

3 ft. (91cm) Minimum

3 ft. (91cm) Minimum

Less than 10 ft. (305cm)

2 ft. (61cm) Minimum

Flat Roof

Figure 29.2