R
VOYAGEUR Wood Insert
Masonry Chimney (Cont’d)
This insert conforms with the UL 1482 and ULC S628 (Canada) in all respects, and is approved to UL & ULC safety standards for installation and use within a fi replace with a masonry chimney in accordance with NFPA 211 and
In USA a minimum 5 foot length, 6 inch diameter fl ue liner is required as per UL 1482, however Hearth & Home Technologies strongly recommends a full reline for optimum performance.
NOTE: In Canada, this fi replace insert must be installed with a continuous chimney liner of a 6 inch (152mm) diam- eter extending from the fi replace insert to the the top of the chimney.
The chimney liner must conform to the Class 3 require- ments of
UL 1777 Insulated Stainless Steel Liner or Other Approved Lining System
Follow Manufacturer’s Instructions on Insulation and Support
For Zero or Other
Masonry Chimney Must
Have Structural Integrity
Follow Manufacturer’s Instructions for Maximum Liner Extension Above Chimney
Maximum 30 Degrees
Offset in Chimney
UL 1777 Insulated Stainless Steel Liner or Other Approved Lining System
Minimum 8 in. (203mm) Masonry Thickness in Front of Smoke Chamber
Minimum Clearance in Accordance
with Insert Listing
Floor Protection in
Accordance with Insert
Listing
COMBUSTIBLE FLOOR
Damper Plate Removed or
Fastened in Open Position
Seal with
NOTE: Generic wood insert shown - not model specifi c
Figure 36.1 - Masonry Chimney with a Full Liner Kit Type UL103HT Rquirement per UL1777
Page 36 | November 22, 2011 |