Quadra-Fire VOYAGEUR-PMH, VOYAGEUR-MBK owner manual Masonry Chimney Cont’d, VOYAGEUR Wood Insert

Models: VOYAGEUR-PMH VOYAGEUR-MBK

1 56
Download 56 pages 52.91 Kb
Page 36
Image 36
Masonry Chimney (Cont’d)

R

VOYAGEUR Wood Insert

Masonry Chimney (Cont’d)

This insert conforms with the UL 1482 and ULC S628 (Canada) in all respects, and is approved to UL & ULC safety standards for installation and use within a fi replace with a masonry chimney in accordance with NFPA 211 and CAN/CSA-B365-01.

In USA a minimum 5 foot length, 6 inch diameter fl ue liner is required as per UL 1482, however Hearth & Home Technologies strongly recommends a full reline for optimum performance.

NOTE: In Canada, this fi replace insert must be installed with a continuous chimney liner of a 6 inch (152mm) diam- eter extending from the fi replace insert to the the top of the chimney.

The chimney liner must conform to the Class 3 require- ments of CAN/ULC-S635, Standard for Lining Systems for Existing Masonry or Factory-Built Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys.

UL 1777 Insulated Stainless Steel Liner or Other Approved Lining System

Follow Manufacturer’s Instructions on Insulation and Support

For Zero or Other Non-Code Clearances, Follow Approved Liner Manufacturer’s Specific Insulation Requirements: Different Clearances May Require Different Specifications

Masonry Chimney Must

Have Structural Integrity

Follow Manufacturer’s Instructions for Maximum Liner Extension Above Chimney

Maximum 30 Degrees

Offset in Chimney

UL 1777 Insulated Stainless Steel Liner or Other Approved Lining System

Minimum 8 in. (203mm) Masonry Thickness in Front of Smoke Chamber

Minimum Clearance in Accordance

with Insert Listing

Floor Protection in

Accordance with Insert

Listing

COMBUSTIBLE FLOOR

Damper Plate Removed or

Fastened in Open Position

Seal with Non-Combustible Material

NOTE: Generic wood insert shown - not model specifi c

Figure 36.1 - Masonry Chimney with a Full Liner Kit Type UL103HT Rquirement per UL1777

Page 36

7063-173D

November 22, 2011

Page 36
Image 36
Quadra-Fire VOYAGEUR-PMH, VOYAGEUR-MBK owner manual Masonry Chimney Cont’d, VOYAGEUR Wood Insert