G. Automatic Combustion Control (ACC)

R

VOYAGEUR Wood Insert

G. Automatic Combustion Control (ACC)

Typically, when you build a fi re, you open the air controls fully and monitor the fi re to prevent it from going into an overfi re situation and/or burning your wood up too quickly before you shut down the air controls to the desired burn rate.

When using the Automatic Combustion Control (ACC) system, you do not have to continually monitor the fi re. Once you set the ACC system it will control the fi re for you. Follow the instructions below to learn how to operate your stove with ease.

H. Air Controls

1. Start-Up Air Control

The function of the Start-Up Air Control is to activate the Auto- matic Combustion Control system (ACC).

• Push the Start-Up Air Control all the way back until it stops

Lift Up on Control and Pull

Away from Appliance

and then pull forward to the front of the appliance until it

 

stops. Figure 10.1.

 

The air channel opens and allows air to enter the front of the appliance for approximately 20-25 minutes.

The air channel gradually shuts down until it is completely closed at the end of the 20-25 minutes.

The fi re is now controlled by the air supplied by the Burn Rate Air Control. Figure 10.1.

This function should be performed each time you reload the appliance.

2. Manual Timer Over-Ride

If you need to shut the ACC system off before it shuts itself off after 25 minutes (i.e. overfi re situation), lift up on the Start-up Air Control and pull away from the appliance. Figure 10.2.

HIGH

Burn Rate Control

LOW

ACC Start-up

Air Control

To activate: Push back until it stops and then pull forward until it stops

Figure 10.2 Manual Timer Over-Ride

3. Burn Rate Air Control

The air supply enters at the upper front of the fi rebox, near the top of the glass door.

This preheated air supplies the necessary fresh oxy- gen to mix with the unburned gases, helping to create the second, third and fourth combustion process.

This air is regulated by the Burn Rate Air Control.

There are four settings High, Medium-High, Medium- Low and Low.

When the control is raised all the way up it is on the High setting and when pushed all the down it is on the Low setting. Figure 11.1.

H. Air Controls WARNING

Risk of Fire or Chimney Fire.

Avoid Overfi re

DO NOT over-ride the Automatic Combustion

Control when the burn rate is set to HIGH

Figure 10.1 Start-up and Burn Rate Air Controls