R

VOYAGEUR Wood Insert

5Service Parts Replacement

UNPLUG APPLICE FROM ANY POWER SOURCE

BEFORE REPLACING ANY COMPONENTS

A. Glass Replacement

(Replace with 5mm ceramic glass only)

1.Ensure that the fi re is out and the appliance is cool to the touch.

2.Protect a table or counter top with padding or towels. Protect your hands and wear gloves to prevent injury.

3.Remove the door with the broken glass by lifting the door up and off of the hinges.

4.Lay door face down on a table or counter making sure the handle hangs over the edge so the door lays fl at, on a soft surface.

5.Remove the screws from each glass retainer and remove the glass. (If screws are diffi cult to remove, soak with penetrating oil fi rst).

B.Snap Disc Replacement (Cont;d)

2.Remove the 2 screws from the blower access assembly and slide assembly away from the appliance

3.Locate the snap disc bracket assembly behind the blower controls on the right side under the ash lip. Figure 22.1

4.Remove the 2 mounting screws in the blower control bracket and slide assembly towards you.

5.Using a Phillips head screw driver, remove the 2 screws from the snap disc and lift the snap disc off of the mounting bracket. Disconect the wires and replace with new snap disc and re-connect the wires.

6.Slide the blower control bracket back into position and secure with the 2 mounting screws.

6.Center the glass with edges evenly overlapping the opening in the door, (i.e. same space top and bottom, left and right sides).

7.Replace the glass retainers. Be careful not to cross thread the screws.

8.Tighten each retainer just a few turns until each is secured. Check again for centering of glass in door frame. Continue to tighten each retainer alternately, a few turns at a time, until the glass is secure. DO NOT OVERTIGHTEN - can cause glass to break.

9.Replace the door on the appliance.

WARNING! Risk of Fire or Injury!

Use only glass that is specifi ed in the manual, DO NOT replace with any other material. Glass breakage will occur.

CAUTION!

Handle glass with care.

Blower Controls & Snap

Disc Under Ash Lip

Snap Disc

Figure 22.1 Snap Disc Location

C. Wiring Diagram

Inspect the gasket to ensure it is undamaged.

Do NOT strike, slam or scratch glass.

Do NOT operate appliance with glass & door assembly removed.

Do NOT operate with glass cracked, broken or scratched.

Quadra-Fire appliances are equipped with ceramic super heat-resistant glass, which can only be broken by impact or misuse.

B.Snap Disc Replacement

1.The grille on the blower access assembly is hinged. Swing the grille downward to expose the 2 screws. Figure 23.1 on page 23.

 

Blower

 

Black

White

 

Snap Disc

 

White

 

 

Power Cord

Black

White

Black

Switch

 

 

 

Rheostat

 

Figure 22.2

Page 22

7063-173D

November 22, 2011

Page 22
Image 22