Chapter 3

Operation

The ARC-101 has several LED indicators, providing information on the ARC-101's general status, as well as right and left module status

(see Figure 3-1). The indicators are ON, OFF, or BLINK, depending on the state of ARC-101. Table 3-1 lists the functions of the front panel indicators.

 

 

Figure 3-1 ARC-101 Front Panel

 

 

Table 3-1 ARC-101 LED Indicators

 

 

 

Name

 

Description

 

 

 

PWR (green)

ON

When ARC 101 is powered.

 

 

 

FLT (red)

BLINKS

Error detected during self-test

 

 

If the error is in one of the modules, the module's two LEDs blink;

 

 

In case of a system error, the two module's LEDs blink.

 

ON

During self-test

ATM (green)

ON

During active ATM connections on the module's port:

 

 

That is when no HEC error was detected during the last second and,

 

 

at least one cell was received and transmitted in the last second.

 

 

 

SYNC (green)

ON

When the module's port is synchronized (no alarm)

 

OFF

During local alarm (a fault is detected on the receive side of ARC-101).

 

BLINKS

During remote alarm the remote unit signals that a fault has been

 

 

detected.

 

 

 

Operating Procedure

3-1

Page 31
Image 31
RAD Data comm ARC-101 operation manual Chapter Operation, Name Description