ARC-101 Installation & Operation Manual Chapter 4. Software Management
Configuration Window 4-3
To Save the Configuration:
CONFIGURATION
1. System Parameters
2. Left Module
3. Right Module
4. ASCII Terminal Configuration
5. Set Default Parameters
6. Save Changes
ESC. Exit
After making all changes, return to the Configuration window, and select
option 6. If a new value was entered at any menu, the following prompt
will appear upon exiting the menu:
ALL CHANGES WILL BE SAVED. ARE YOU SURE? (Y/N)
Type Y for "Yes", or press any other key for "No".
Note If you change a module, the ARC-101 will reboot with its default parameters.
To Set Default
Parameters
To return all configuration parameters to their factory defaults, go to the
Configuration window, and select option 5.
Note If you set the Default Parameters, the Baud Rate parameter will be changed
and saved as 9600. The ASCII Terminal Baud will be changed to 9600 the next
time the ARC is restarted.

System

Parameters

To set system parameters, select option 1 from the Configuration menu.
SYSTEM PARAMETERS
1. FIFO Congestion Threshold: 90%
2. EFCI Marking: Disable
3. CLP Dropping: Disable
4. Early Packet Discard: Disable
ESC. Exit
Select item from the menu:
FIFO Congestion
Threshold
(Default - 75%); options: 25%, 50%, 75%, 90%, 100%
The FIFO threshold in which the ARC-101 will enter the "congestion" state