Chapter 4. Software Management

ARC-101Installation & Operation Manual

 

 

 

The options are 25%, 50%, 75%, 90% and 100%.

EFCI Marking

(Default - Disable); options: Enable, Disable

 

Enables EFCI marking while FIFO is in congested state. Setting this

 

parameter to Enable causes the EFCI marking of all cells that are received,

 

while FIFO is in a congested state.

 

CLP Dropping

(Default - Disable); options: Enable, Disable

 

Enables CLP dropping when FIFO is congested. Setting this parameter to

 

Enable causes cells - with CLP bit set - to be dropped, if they are received

 

while FIFO is in a congested state.

 

Early Packet

(Default - Disable); options: Enable, Disable

Discard

 

 

Enables entire frame, except for last cell, to be dropped when FIFO is congested. Setting this parameter to Enable causes frames to be dropped, if they are received while FIFO is in a congested state.

Right/Left

Module

Configuration

The two windows (Left and Right module configuration, options 2 and 3 in the Configuration menu) are identical.

LEFT MODULE

1.Port Enable/Disable: Enable

2.Transmit Clock Source: Loopback

3. Loopback State:

Disable

4.SONET/SDH Frame Type: STM-1 (SDH)

ESC. Exit

Port Enable/Disable (Default - Enable); options: Enable, Disable

If the port is Disabled, no data will be received at the port. Transmit functions are not changed. Remote loop is still available. If the port is Enabled, received data is transferred to the other port.

Transmit Clock (Default - Local timing); options: Local timing, Loopback timing

Source

This parameter selects the clock source for the transmit clock. "Local timing" selects the clock that is derived from the oscillator on board. "Loopback timing" selects the clock recovered from the received data to be the source. Note that for an E1 interface, the default is "Loopback timing" and should not be changed. Do not configure the module for Loopback timing while it is in Internal Loopback mode.

4-4

Configuration Window

Page 38
Image 38
RAD Data comm ARC-101 operation manual Right/Left Module Configuration