Raymarine ST60 manual Stand alone instruments

Models: ST60

1 52
Download 52 pages 43.38 Kb
Page 38
Image 38
Stand alone instruments

26

ST60 Wind & Close Hauled Wind Instrument Owner’s Handbook

 

Red

 

 

 

 

 

5 A fused,

1

2

3

4

 

12 V dc supply

 

(typically provided

 

 

 

 

 

by autopilot)

 

 

 

 

 

Screen

 

 

 

 

 

 

 

 

 

Instruments

 

Red

 

 

 

5 to 16

 

 

 

 

 

 

Screen

20

19

18

17

 

SeaTalk power connections

 

 

 

D4311-1

Stand alone instruments

Stand-alone instruments are not connected to SeaTalk and therefore need to be connected to an alternative 12 V power source. Power cables are available in 2 m and 9 m lengths.

To fit a power cable:

1.Ensure the intended power source is switched off.

2.Run the power cable from the instrument to a suitable 12 V dc power source.

3.If the cable has not already been trimmed at the power supply end:

i.Cut the cable to length and trim back an appropriate amount of the outer sheath.

ii.Cut back and insulate the yellow wire.

4.Connect the screen to the power supply 0 V terminal.

5.Connect the red wire via a 3 A circuit breaker to the power supply +12 V ter- minal.

6.Insert the power cable connector into one of the SeaTalk connectors at the rear of the instrument.

12 V dc

supply

3 A over-current

circuit breaker

Red

Screen

Power connections for stand-alone instrument

D4310-4

Page 38
Image 38
Raymarine ST60 manual Stand alone instruments