Regency G36D installation manual Vertical Termination With Co-Linearflex System, Installation

Models: G36D

1 44
Download 44 pages 31.34 Kb
Page 18
Image 18
VERTICAL TERMINATION

INSTALLATION

VERTICAL TERMINATION

WITH CO-LINEAR FLEX SYSTEM

THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE.

This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney. See the Venting Arrangements on next page for minimum and maximum heights.

Required Parts:

Part #

Description

946-529

Co-linear DV Vertical

 

Termination Cap

948-305

3" Flex - 35 ft.

946-563

Co-Axial to Co-Linear Adapter

Kit

which contains the following:

 

 

Co-linear Flex Adapter

 

Outer Pipe

 

Inner Pipe Adapter

510-994

Rigid Pipe Adaptor

Masonry chimneys may take various contours which the fl exible liner will accommodate. However, keep the flexible liner as straight as possible , avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

Co-linear DV

 

Vertical Termination

 

Cap # 946-529

 

A maximum

 

of two certified

 

joiner kits

 

may be used

 

per length.

Flex Liner

#948-305 (35 ft)

 

Alternate Approved Caps

980Vertical Termination Cap

991High Wind Cap

923GK 3" Co-linear Adapter with fl ashing

Exhaust Flue

FPI Cabinet and/or Flat Wall Mantles may be used in these applications ensuring that clearances to combustibles are maintained.

Outer

Pipe

with Kit# 946-563

Pipe Length

Manual backgroundAir Intake

 

 

Co-Linear

 

 

Flex

 

 

Adapter

Rigid Pipe Adaptor

 

with Kit#

 

946-563

# 510-994

90 Degree

 

 

Elbow

Inner Pipe

 

 

 

 

Adapter

 

 

with Kit#

 

 

946-563

18

UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace

Page 18
Image 18