INSTALLATION

This includes:

1)Clocking the appliance to ensure the correct fi ring rate (rate noted on label 26,000 Btu/h) after burning appliance for 15 minutes.

2)If required, adjusting the primary air to ensure that the fl ame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

LOCATING YOUR

GAS STOVE

5)This appliance is Listed for bedroom installations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

6)The G36D Direct Vent Gas Fireplace is approved for alcove installations, which meet the clearances listed on this page.

7)Werecommendthatyouplanyourinstallation on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have a qualifi ed inspector, dealer, or installer review your plans before installation.

Note: For vent terminations see the "ExteriorVentTerminationLocations" section.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

1)Ensure that structural members are not cut or weakened during installation.

2)Ensure proper grounding using the #8 ground lug provided. Refer to the "Wiring Diagram" section.

1)When selecting a location for your fi replace, ensure that the clearances outlined on this page are met.

2)Provide adequate clearances for servicing.

3)The appliance must be installed on a fl at, solid, continuous surface (e.g. wood, metal, concrete). This may be the fl oor, or raised up on a platform to enhance its visual impact. If the appliance is going to be installed on carpeting, combustible linoleum tile or other combustible material other than wood

ooring, the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

4)The G36D Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A, B, C, D. See Diagram 1.

A)Flat on Wall

B)Flat on Wall Corner

C)Recessed into Wall/Alcove

D)Corner

Diagram 1

G36D UNIT DIMENSIONS

6

UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace

Page 6