INSTALLATION

15)Using the Allen wrench as shown in Fig.4, rotate the screw clockwise until snug, do not overtighten.

Fig.

WARNING!

Do not overtighten the screw

Recommended to grip the wrench by the short side.

16)Verify that if the conversion is from NG to LPG, the screw must be re assembled with the red o-ring visible (Fig. 5)

WARNING!

Also check that the pilot

and main burner injectors are

appropriate for the gas type.

18)Reverse steps 5) to 2)

19)Attach the label "This unit has been converted to LPG" near or on top of the serial # decal.

20)Replace yellow "Natural Gas" label with red "Propane" label.

Installation of the DC Sparker:

21)Locate the Piezo Ignitor situated at the side of valve.

Piezo

Ignitor

24)I nstall the 3/4" nylon plug to cover up the hole on the mounting bracket.

25)Connect the DC spark generator wires to the SIT Valve with the screw which is provided in the kit.

Red o-ring visible

LPG Configuration

22)Remove the Piezo Ignitor by unscrewing the nut at the back of the mounting bracket.

26)Locate the ground lug at the receptical box, left of the unit.

Fig.5

Ignitor

Wire

17)Re-assemble the black protection cap (Fig. 6)

Fig. 6

Piezo

Ignitor

23)Disconnect the ignitor wire from the Piezo Ignitor and connect it to the D.C. Sparker

DC

Sparker

Ignitor

Wire

27)Connect one end of the supplied green ground wire to the lug with the nut and washer from the kit.

Ground

wire from

kit

UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace

25

Page 25
Image 25
Regency G36D installation manual Piezo Ignitor, Sparker Ignitor Wire, Ground Wire from Kit