INSTALLATION

CONVERSION KIT #773-969 FROM NG TO LPG

FOR G36D-1 USING SIT 820 NOVA GAS VALVE

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!

Each Kit contains one LPG Conversion Kit and one DC Sparker Kit.

LPG Conversion Kit Contains:

11 ) Remove the black protection cap by hand from the high-low knob (Fig.1).

Qty. Part #

Description

1904-345 Burner Orifi ce #53

1908-528 Red "LPG" labe l

1908-255 Label "Converted to LPG "

1908-529 5/32" Allen Key

1910-037 LP Injector (Pilot Orifi ce)

1918-476 Instruction Sheet

DC Sparker Kit Contains:

Qty. Part #

Description

1820-475 Bracket DC Sparker

1820-476 Bracket DC Sparker

1904-153 Washer #8 External Star

1904-330 Nut 8-32 Hex

1904-438 Plug Nylon 0.750 Hole, Black

2904-531 Bushing Split Plastic

0.500 in

1904-543 Screw 8-32 x 3/4 Pan Head

2904-553 Screw #8 x 1/2 Type "B",

Black Oxid e

1910-073 Spark Generator Battery Holder

1910-074 Spark Generator Switch C/W Wire

1910-078 Battery Size AA

Energizer En91

Remove the 2 screws, push Burner Assembly to the left and lift out.

6)Pull off the pilot cap to expose the pilot orifi ce

7)Unscrew the pilot orifi ce with the allen key and replace with the LP pilot orifi ce in the kit and replace pilot cap.

Fig. 1

12)Insert a 5/32or 4mm Allen wrench into the hexagonal key-way of the screw (Fig. 2), rotate it counter-clockwise until it is free and extract it

1910-199 Clip Wire Holder

1910-903 Wire Fan To Power Cord Ground 30 in

1910-480 Instruction Sheet

904-781 Velcro Hook, Black

904-782 Velcro Hook, Black

Installation of LPG

Conversion Kit:

1)Shut off the gas supply

2)Remove the louvers (and bay door if it is installed)

3)Open the fl ush door and remove the door

4)Remove the logs and embers

5)Remove the 2 screws holding the Burner Assembly to the fi rebox base. Push the Burner Assembly to the left and lift out

8)Remove burner orifice with a 1/2" wrench and discard. Use another wrench to hold on to the elbow behind the

orifi ce

Burner Orifice

9)Reinstall new burner orifice LP stamped #53 and tighten

10)Tu rn control knob to the OF Fposition

Fig.2

13)Check that the screw is clean and if necessary remove dirt.

14)Flip the screw (Fig. 3).

24

UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace

Page 24
Image 24
Regency G36D Installation of LPG Conversion Kit, LPG Conversion Kit Contains, DC Sparker Kit Contains Qty, Orifi ce