Regency L676 installation manual Installation, Mantel Clearances, Mantel Leg Clearances

Models: L676

1 56
Download 56 pages 33.98 Kb
Page 10
Image 10
MANTEL CLEARANCES

INSTALLATION

INSTALLATION

MANTEL CLEARANCES

Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram below.

Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.

Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.

MANTEL LEG CLEARANCES

Combustible mantel leg clearances as per diagram:

MANTEL LEG

L676 UNIT

Non-combustible

Facing

4" 1.5"

Allowable mantel

9" (229mm)

leg projection

 

 

11" (279mm)

Side wall

15” (381mm)

 

10

Regency® L676 Direct Vent Gas Fireplace

Page 10
Image 10
Regency L676 installation manual Installation, Mantel Clearances, Mantel Leg Clearances