Bottom Brick Panel

INSTALLATION

13) Carefully remove the bottom brick panel.

17) Disconnect the 2 connectors from the

20) Disconnect the black and red wires from

 

modulating coil.

the solenoid valve.

INSTALLATION

Bottom Brick Panel

14)Loosen the 2 screws that hold the right side heat shield.

Heat

Shield

15)Lift up and pull out the heat shield slightly to clear the head screws and then hang it on the top bracket (located directly above the heat shield).

Bracket

Heat

Shield

18)Remove the DC Sparker wires; 1 wire for the ignitor and 2 wires to the module box.

19)Remove the 16 screws that hold the valve tray to the firebox and slightly pull out the valve tray.

Valve Tray

21)Disconnect the 2 red wires and 1 black wire from the valve.

Modulating Coil

Wires

22)Completely pull out the valve tray.

23)Replace the front burner orifice with orifice #56. See image below. Use another wrench to hold onto the elbow behind the orifice.

24)Replace the back burner orifice with orifice #53. See image below. Use another wrench to hold onto the elbow behind the orifice.

Front Burner

Rear Burner

Orifi ce

Orifi ce

16)Disconnect the inlet gas line from the valve.

Valve Tray Slightly Removed