INSTALLATION

LOG SET INSTALLATION

Installation of Interior Brick Panels must be completed before installing the log set.

INSTALLATION

Read the instructions below carefully and refer to the diagrams. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation.

Log kit (Part No. 521-930 and 521-935) contain the following pieces:

a)

03-25

Log Rear

b)

03-26

Log Top

c)03-27 Log Front Left

d)03-28 Log Front Right

e)902-154 Embers Lava

f)902-179 Vermiculite

03-25

03-27

03-28

3)Place log 03-27 on the front left side of the burner. Place the right end of the log into the pin and rest the left end of the log inbetween the rear and front burner tubes.

03-27

Rear

Burner

Tube

Front Burner Tube

4)Place the left end of log 03-28 into the pin while resting the right end of the log on the grate. Slide the right end of the log forward until it is approximately 3/8" away from the back side of the grate.

03-28

03-26

The "03" reference numbers (i.e. 03-25) are

molded into the rear of each log.

1)Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.

2)Place log 03-25 on the rear log support pins.

Backside of Grate

5) Line up the two holes on the underside of log 03-26 with the pins on logs 03-25 and 03-27 and fit in place.

03-26

03-25

03-25

03-27

36

Regency® L676 Direct Vent Gas Fireplace

Page 36
Image 36
Regency L676 installation manual LOG SET Installation, Rear Burner Tube Front Burner Tube, Backside of Grate